whatsapp: 0086-18615575385
whatsapp: 0086-13668821631

Free And Forced Convection Didactic Equipment Vocational Education Equipment Thermal Lab Equipment

Item No.: WL 440
Free And Forced Convection Didactic Equipment Vocational Education Equipment Thermal Lab Equipment
Description
WL 440 Free And Forced Convection Didactic Equipment Vocational Education Equipment Thermal Lab Equipment

Calculation of convective heat transfer at different geometries: flat plate, cylinder, tube bundle
Features
- free and forced convection using the example of various heating elements
- network capability: network access to ongoing experiments by any number of external workstations
- software: operation and control of the experimental unit, data acquisition and  educational software
- E-Learning: multi-media didactic materials accessible online
Learning objectives/experiments
- free and forced convection
- calculation of convective heat transfer at different geometries
-- flat plate
-- cylinder
-- tube bundle
- experimental determination of the Nusselt number
- calculation of typical characteristic variables of heat transfer
-- Nusselt number
-- Reynolds number
- investigation of the relationship between flow formation and heat transfer during experiments
- description of transient heating process
- E-Learning
-- multi-media online course, which enables learning independent of time and place
-- access via Internet browser
-- educational software including different learning modules
-- course in the fundamentals
-- detailed thematic courses
-- check through targeted review of the learning objectives
-- authoring system with editor that enables you to integrate your own, local content into the educational software
Specification
[1] investigate heat transfer in the air duct by forced convection
[2] study of free convection
[3] air duct with axial fan
[4] 4 heating elements with different geometries
[5] continuously adjustable heating and fan power
[6] display of temperatures, heating power and air velocity in the software
[7] due to integrated microprocessor-based instrumentation no additional devices with error-prone wiring are required
[8] functions of the software: system operation, data acquisition, educational software
[9] network capability: LAN/WLAN connection of any number of external workstations with software for observation and evaluation of the experiments
[10] E-Learning: online multi-media didactic materials
[11] software for data acquisition via USB under Windows 10


Technical data
Air duct
- flow cross-section: 120x120mm
- height: approx. 0,6m
Heating elements, temperature limitation: 90°C
- tube bundle
-- number of tubes: 23
-- one tube in variable position is heated
-- heating power: 20W
-- heat transfer area: 31,41cm2
- cylinder with an even temperature at the surface
-- heating power: 20W
-- heat transfer area: 111cm2
- plate
-- heating power: 40W
-- heat transfer area: 2x 100cm2
- cylinder with heating foil to investigate the local heat transfer
-- heating power: 40W
-- heat transfer area: 111cm2
Axial fan
- max. flow rate: 500m3/h
- max. pressure difference: approx. 950Pa
- power consumption: 90W
Measuring ranges
- air velocity: 0...10m/s
- temperature: 4x 0...325°C
- heating power: 0...50W
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase
UL/CSA optional
LxWxH: 670x350x880mm; Weight: approx. 25kg