whatsapp: 0086-18615575385
whatsapp: 0086-13668821631

Instantaneous Gas Heater Didactic Equipment Vocational Training Equipment Thermal Lab Equipment

Item No.: HL 500
Instantaneous Gas Heater Didactic Equipment Vocational Training Equipment Thermal Lab Equipment
Description
HL 500 Instantaneous Gas Heater Didactic Equipment Vocational Training Equipment Thermal Lab Equipment

Methods of gas burner adjustment; simulation of twelve faults
Features
- methods of gas burner adjustment
- simulation of twelve faults
Learning objectives/experiments
- gas burner adjustment by volumetric method
- nozzle pressure method for gas burner adjustment
- fault finding
Specification
[1] simulation of an instantaneous gas heater
[2] safe operation of heater using air


[3] diaphragm pump for pressure generation
[4] PLC simulation of safety functions
[5] simulation of 12 faults by PLC
Technical data
Instantaneous heater
- nominal thermal output: 19,2kW
Diaphragm pump
- max. flow rate: 70L/min
Gas pressure controller: 16...28mbar
Measuring ranges
- pressure:
-- 0...6bar (water)
-- 0...60mbar (gas)
- differential pressure: 10-0-10mbar
- flow rate:
-- 0,75...7Nm3/h (gas)
-- 75...1000L/h (water)
230V, 50Hz, 1 phase
120V, 60Hz, 1 phase
230V, 60Hz, 1 phase
UL/CSA optional
LxWxH: 1650x800x1850mm
Weight: approx. 100kg